SITE DESCRIPTION
Treated Volume |
1137 |
Thermal technology | Dynamic LNAPL Skimming |
Main contaminant | Kerosen |
| Site challenges |
strict security procedures and minimal disruption to ongoing operations.
|
Project Timeline | 05/2023 - 09/2024 |
SOLUTION
Treatment Method | Dynamic LNAPL recovery using skimmers |
Treatment program | Intallation of 3 skimmers at 12 meters deep for 6 months |
Contaminated Vapors Management | Not applicable |
Process control | PLC to adjust pumping cycles for continuous pumping, monthly visit to manage LNAPL level |

RESULTS
✅ Continuous recovery of free-phase hydrocarbons |
✅ Automated groundwater pumping and LNAPL skimming |
✅ Effective remediation |