Thermal Remediation of DNAPL and LNAPL Contamination in Allerød, Denmark

Approximately 288 m³ of soils impacted by chlorinated solvents were successfully remediated using In-Situ Thermal Desorption, achieving cleanup objectives for PCE/TCE contamination beneath a high-voltage transformer installation.

Site description

Treated volume288 m³of contaminated soil (524 t)
Thermal technologyIn-Situ Thermal Treatment
Main contaminantPCE/TCE; oil also present
Site challengesTreatment directly beneath a high-voltage transformer of a power station
Project timeline2016
Project site

Solution

  • Treatment method15 heating tubes (8.8–9.2 m) and 24 steam tubes connected to an extraction system; propane burners
  • Treatment programPit of 6 × 6 m, 1 m deep; target temperature 88°C; 42 days of heating
  • Contaminated vapour managementNon-condensable gases burned to meet discharge standards; condensate collected and treated at the GEO facility
  • Process controlAnalysis of gases and condensate during treatment
Treatment on site

Results

No chlorinated solvent residues detected in the soil
288 m³treated soil volume
Chlorinated solvent target (<0.1 mg/kg) achieved
Site during or after treatment

Reference sheet

Technical summary of this project, sent on request.

Facing a similar site?

Send us your site details and our team will prepare a tailored proposal.